EasyManuals Logo

Ness D-16 User Manual

Ness D-16
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
3232
3232
32
PROGRAMMING
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
RADIO SUPERVISION ALERTS - RESET OUTPUT
Setting this option turns the Reset output ON when a SUPERVISED RADIO alert
occurs. The Reset output will remain ON for the duration of the ALARM TIME
(Set by Option P29E).
PROGRAMMING SEQUENCE:
P66E 1E toggles the option ON and OFF
P66E 1E OFF: Supervision Reset output disabled
P66E 1E ON: Supervision Reset output enabled
P66E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Supervision Reset output disabled
NOTES:
RELATED OPTIONS:
P65E Supervised Radio Zones
RADIO SUPERVISION ALERTS - STROBE OUTPUT
Setting this option turns the Strobe output ON when a SUPERVISED RADIO
alert occurs. The Strobe output will remain ON until the panel is disarmed.
PROGRAMMING SEQUENCE:
P66E 2E toggles the option ON and OFF
P66E 2E OFF: Supervision Strobe output disabled
P66E 2E ON: Supervision Strobe output enabled
P66E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Supervision Strobe output disabled
NOTES:
RELATED OPTIONS:
P65E Supervised Radio Zones
RADIO SUPERVISION ALERTS - KEYPAD SONALERT & DELAY
ALL SUPERVISION OUTPUTS
Setting this option turns the Keypad Sonalert ON when a SUPERVISED RADIO
alert occurs. The Keypad Sonalert remains ON until any keypad key is pressed.
Also, turning this option ON makes all Supervision outputs delayed by one
minute.
PROGRAMMING SEQUENCE:
P66E 3E toggles the option ON and OFF
P66E 3E OFF: Supervision Keypad Sonalert disabled
AND all Supervision outputs trigger instantly
P66E 3E ON: Supervision Keypad Sonalert enabled
AND all Supervision outputs are delayed by 1 minute
P66E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Supervision Keypad Sonalert disabled
NOTES:
When this option is turned ON, it delays
the operation of all other selected
Supervision outputs by one minute.
RELATED OPTIONS:
P65E Supervised Radio Zones
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Supervision RESET output
Supervis STROBE outpution
Supervis SONALERT outpu
t
ion
Supervis SIREN outpution
Supervis AUX1 outpution
Supervis AUX2 outpution
Supervis speedup x6ion
Supervis speedup x10ion
OPTION No DESCRIPTION
P66E Radio Supervision Alerts
Technical Manuals Online! - http://www.tech-man.com