PROGRAMMING
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
3K3 ZONE RESISTORS
Setting this option ON changes the Zones 1 – 8 monitoring resistor from 2K2 to
3K3. (External Tamper input always uses a 2K2 resistor).
This option has no effect if Zone splitting has been selected with the P68E 1E
option.
PROGRAMMING SEQUENCE:
P68E 2E toggles the option ON and OFF
P68E 2E OFF: 3K3 zone resistors disabled
P68E 2E ON: 3K3 zone resistors enabled
P68E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No 3K3 zone resistors
NOTES:
• The 3K3 zone resistor option is useful
when installing the panel in a site pre-
wired with 3K3 resistors
• If Zone 8 is converted to a keyswitch
input then a 2K2 monitoring resistor is
always used
RADIO KEY PANIC TOGGLES AUX1
Setting this option ON changes the action of the Radio Key Panic button so that
the AUX1 output is toggled ON and OFF. (Each press on Panic toggles the
state of AUX1 between ON and OFF).
If an RK4 radio key is used then this option can be used with the AUX button
instead of the Panic button (using P68E 7E, 8E). This then allows the Panic key
to still activate Panic reports.
PROGRAMMING SEQUENCE:
P68E 3E toggles the option ON and OFF
P68E 3E OFF: Radio Key Panic triggers control panel Panic
P68E 3E ON: Radio Key Panic toggles AUX1
P68E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Radio Key Panic to AUX1 disabled
NOTES:
• This option is useful for triggering
external devices using Radio Key’s Panic
button. E.g., lighting, garage doors
• When this option is selected ON, the
Radio Key Panic function is disabled.
See: TABLE, RADIO KEY TO AUX1
RADIO KEY PANIC PULSES AUX1
Setting this option ON changes the action of the Radio Key Panic button so that
the AUX1 output is pulsed ON for 2 seconds. (That is; momentary ON for 2sec).
If an RK4 radio key is used then this option can be used with the AUX button
instead of the Panic key (using P68E 7E). This then allows the Panic key to still
activate Panic reports.
PROGRAMMING SEQUENCE:
P68E 4E toggles the option ON and OFF
P68E 4E OFF: Radio Key Panic triggers control panel Panic
P68E 4E ON: Radio Key Panic pulses AUX1
P68E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Radio Key Panic to AUX1 disabled
NOTES:
• When this option is selected ON, the
Radio Key Panic function is disabled.
• If P68E 3E and 4E are both selected ON,
then 4E has priority.
See: TABLE, RADIO KEY TO AUX1
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
Zone split
3K3 zone resistors
Radio Key Panic toggles AUX1
Radio Key Panic pulses AUX1
Radio Key Arming unsealed warning
24hr zone fire siren sound
4th button Radio Key for AUX1
Quiet chirps on Arm/Disarm
OPTION No DESCRIPTION
P68E Miscellaneous options
ZONE SPLIT
See page 35
P68E 1E
Technical Manuals Online! - http://www.tech-man.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D-16 and is the answer not in the manual?

Ness D-16 Specifications

General IconGeneral
BrandNess
ModelD-16
CategoryControl Panel
LanguageEnglish

Related product manuals