PROGRAMMING
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
1E 2E 3E 4E 5E 6E 7E 8E
ON = Factory default setting.
AREA1 Open/Close repor
t
AREA2 Open/Close repor
t
Chirp Siren on kiss-off
Flash Strobe on kiss-off
Forced Opening report
Delay Closing report
Manual Exclude report
Auto Exclude report
OPTION No DESCRIPTION
P88E Open/Close reporting options
ONONON
AREA1 OPEN/CLOSE REPORTS
Enables or disables sending of AREA1 Open/Close reports.
The User ID of the code used is included in the report. Keyswitch Arming and
Shortcut Arming are identified as User 15.
PROGRAMMING SEQUENCE:
P88E 1E toggles the option ON and OFF
P88E 1E OFF: No AREA1 Open/Close reports
P88E 1E ON: AREA1 Open/Close reports enabled
P88E 1E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No AREA1 Open/Close reports
NOTES:
AREA2 OPEN/CLOSE REPORTS
Enables or disables sending of AREA2 Open/Close reports.
PROGRAMMING SEQUENCE:
P88E 2E toggles the option ON and OFF
P88E 2E OFF: No AREA2 Open/Close reports
P88E 2E ON: AREA2 Open/Close reports enabled
P88E 2E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No AREA2 Open/Close
NOTES:
SIREN CHIRP ON KISS-OFF
Selects a 2 Second Siren burst on a successful Closing report. This is used to
give audible indication that the dialler has successfully sent the Arming report.
PROGRAMMING SEQUENCE:
P88E 3E toggles the option ON and OFF
P88E 3E OFF: No Siren Chirp on kiss-off
P88E 3E ON: Siren Chirp on kiss-off enabled
P88E 3E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Siren Chirp on kiss-off
NOTES:
RELATED OPTIONS:
P88E 4E Flash Strobe on kiss-off
STROBE FLASH ON KISS-OFF
Selects a 2 Second Strobe on a successful Closing report. This is used to give
visual indication that the dialler has successfully sent the Arming report.
PROGRAMMING SEQUENCE:
P88E 4E toggles the option ON and OFF
P88E 4E OFF: No Strobe Flash on kiss-off
P88E 4E ON: Strobe Flash on kiss-off enabled
P88E 4E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: No Strobe Flash on kiss-off
NOTES:
RELATED OPTIONS:
P88E 3E Siren Chirp on kiss-off