PROGRAMMING
NESS D16 (V4.6) CONTROL PANEL - INSTALLER MANUAL
FORCED OPENING REPORT
If Forced Opening Report is selected ON - when an alarm has been reset by a
valid User Code (or Radio Key), the dialler will send an Opening report along
with a restoral report for the zone or miscellaneous input which caused the
alarm.
PROGRAMMING SEQUENCE:
P88E 5E toggles the option ON and OFF
P88E 5E OFF: No Forced opening Reports
P88E 5E ON: Forced opening Reports enabled
P88E 5E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Forced opening Reports enabled
NOTES:
• This option is used to indicate to the
Central Station that an alarm has been
reset by a valid user.
Usually used in cases where Open/Close
reports are normally selected OFF.
DELAY CLOSING REPORT
If selected ON, Closing reports (if enabled) are sent at the end of Exit Time.
Normally, Closing reports are sent immediately on Arming.
PROGRAMMING SEQUENCE:
P88E 6E toggles the option ON and OFF
P88E 6E OFF: Closing Reports sent on Arming
P88E 6E ON: Closing Reports sent at end of Exit Time
P88E 6E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
OFF: Closing Reports sent on Arming
NOTES:
RELATED OPTIONS:
P88E 1E AREA1 Open/Close reports
P88E 2E AREA2 Open/Close reports
MANUAL EXCLUDE REPORT
Enables Manual Exclude Reports for Zones 1-16. Exclude Reports for 24hr
zones are sent on exiting EXCLUDE mode.
PROGRAMMING SEQUENCE:
P88E 7E toggles the option ON and OFF
P88E 7E OFF: No Manual Exclude Reports
P88E 7E ON: Manual Exclude Reports enabled
P88E 7E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Manual Exclude Reports enabled
NOTES:
RELATED OPTIONS:
P88E 8E Auto Exclude Reports
AUTO EXCLUDE REPORT
Enables Auto Exclude Reports for Zones 1-16. Zones not sealed on Arming will
be reported as Auto Excluded..
PROGRAMMING SEQUENCE:
P88E 8E toggles the option ON and OFF
P88E 8E OFF: No Auto Exclude Reports
P88E 8E ON: Auto Exclude Reports enabled
P88E 8E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
ON: Auto Exclude Reports enabled
NOTES:
P88E 7E Manual Exclude Reports
Technical Manuals Online! - http://www.tech-man.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D-16 and is the answer not in the manual?

Ness D-16 Specifications

General IconGeneral
BrandNess
ModelD-16
CategoryControl Panel
LanguageEnglish

Related product manuals