NESS D8 V4.7 CONTROL PANEL - USER MANUAL
23
PROGRAMMING
EXAMPLES The panel must be in program mode. (Program light ON).
To program User Code 1 to be 1234: P11E 1234 E 1234 E
To program User Code 2 to be 5678 and an ARM ONLY code : P12E ARM E 5678 E 5678 E
When an Arm Only code is displayed, the ARM light or icon is displayed before the digits of the code
To deselect the Arm Only feature for a particular user code, simply enter the option for that code and press ARM E
without re-entering a new code. This retains the existing code and toggles off the Arm Only feature.
To delete User Code 2: P12E MEMORY E
USER CODE PROGRAMMING RULES:
All codes can be 3, 4, 5 or 6 digits long.
Codes beginning with 0 (zero) can be programmed but they will not operate the panel. This is an alternative method
for disabling user codes, however the MEMORY E function is recommended for deleting user codes.
Codes are rejected if already used. Some codes that are similar to existing codes may also be rejected.
The Master Code, (User Code 1), cannot be an ARM ONLY code.
The Master Code must always be programmed, all other codes are optional.
Enters Program Mode. The PROGRAM light will be on. Enters Program Mode. The PROGRAM light will be on.
The two digit option number for the code to be programmed.
The existing code (if any) will be displayed. The existing code (if any) will be displayed.
The two digit option number for the code to be programmed.
To exit Program Mode
To exit Program Mode
Enter the new code twice. The new code will be displayed.
The existing code has now been erased. The existing code has now been erased.
Enter the new code twice. The new code will be displayed.
[Master Code] [Master Code]
[Option No.]* [Option No.]*
[NEW CODE] [NEW CODE] [NEW CODE]
[NEW CODE]
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
Press... Press...
Press... Press...
Press...
Press...
Press...
Press...
Press...
Press...
LED KEYPAD
PROGRAMMING USER CODES
LCD KEYPAD
DELETING USER CODES
At Step 3, enter MEMORY E, instead of a new code.
* For a list of programming option numbers, see the Programming Options Table on page 22.

Other manuals for Ness D8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ness D8 and is the answer not in the manual?

Ness D8 Specifications

General IconGeneral
BrandNess
ModelD8
CategoryControl Panel
LanguageEnglish

Related product manuals