NESS D8 V4.7 CONTROL PANEL - USER MANUAL
32
OPERATION SUMMARY
ARM
DISARM
MONITOR MODE
PANIC
KEYPAD DURESS
EXCLUDING ZONES
VIEW MEMORY
or...
or...
or...
or...
or...
Press repeatedly to display the last
30 events
or...
Both keys together
(Keypad Panic Shortcut
must be ON, P62E 4E)
(Arming Shortcut
must be ON, P62E 5E)
(Monitor Shortcut
must be ON, P62E 3E)
(Monitor Shortcut
must be ON, P62E 3E)
(Arming Shortcut
must be ON, P62E 5E)
(Exclude Shortcut
must be ON, P62E 2E)
(Memory Shortcut
must be ON, P62E 1E)
(Memory Shortcut
must be ON, P62E 1E)
(Exclude Shortcut
must be ON, P62E 2E)
Press and hold for 4 seconds
(P68E 3E & 4E must be OFF)
Press OFF button twice within 4 seconds
or ON button twice within 4 seconds
P69E 5E must be ON
or
[User Code]
[User Code]
[User Code]
[User Code]
[User Code]
[Zone No.]
[Zone No.]
[User Code][5, 6, 8 or 9]
[User Code]
The panel must be in
a Disarmed state first.
The panel must be in
a Disarmed state first.*
* NOTE: Normal user codes can arm the panel only if it is fully disarmed first.
User codes that are programmed to be Arm Only codes can arm the panel from Monitor mode or from the disarmed state.
LED KEYPAD
OPERATION
LCD KEYPAD RADIO KEY
PANIC
PANIC
PANIC
PANIC
ARM
ARM
MONITOR
MONITOR
EXCLUDE
EXCLUDE
MEMORY
MEMORY
MEMORY
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
To Disarm and report a Duress Alarm, add any of the digits 5, 6, 8 or 9 before the
User Code when Disarming.
P75E1E must be enabled
Keypad Duress is factory
defaulted for silent reporting
EXCLUDE + ENTER can only
be used when the panel is
disarmed.
EXCLUDE + CODE + ENTER
can be used when the panel
is armed or disarmed.
View Memory can only be
used when the panel is
disarmed.
Enter the zone numbers
to be Excluded
To exit Exclude mode
To exit Memory mode
x 2 x 2
Hold
Press repeatedly to display
the last 30 events
Both keys together
(Keypad Panic Shortcut
must be ON, P62E 4E)
or...
or...
or...
or...
or...
or...
[Zone No.]
[Zone No.]
[]5, 6, 8 or 9
[User Code]
[User Code]
[User Code]
[User Code]
[User Code]
[User Code]
[User Code]
Enter the zone numbers
to be Excluded
To exit Exclude mode
To exit Memory mode
To Disarm and/or reset
alarms.
TEMPORARY DAY
ZONES
The panel must be in
a Disarmed state first.*
P64E 2E must be on for
enable the use of
Temporary Day Zones.
Note: On the Ness LED keypad, the 'E' button is labelled 'ENTER' and the 'P' button is labelled 'PROGRAM'.
[Zone No.]
Enters Temporary Day Zone selection mode.
Enables/disables Temporary Day mode.
Select zone/s to be Temporary Day Zones.
Saves changes and exits Temporary Day Zone selection mode.