NESS D8 V4.7 CONTROL PANEL - USER MANUAL
9
OPERATION
The control panel must be Armed prior to
vacating the premises in order to detect intruders.
The panel must be disarmed and not in Program,
Monitor, Memory or Exclude modes.
Note: If the panel is already in alarm, you must fi rst
silence the alarm before you can Arm.
If something is wrong when Arming the control
panel, the normal 3 beeps will be replaced by
other warnings.
10
10 beeps means Mains Power is
turned off or the Backup Battery is low.
One long beep indicates an invalid
entry or an alarm is outstanding and needs to
be reset by entering your User Code fi rst.
SIREN WARNING:
At the end of the exit time, all zones should
be Sealed. If any are Unsealed, the siren will
sound for 2 seconds as a warning to indicate
that those zones have been automatically
excluded. For maximum security, you should
return, Disarm, check the premises and then
Arm again. Continual warnings could mean
that a detector is faulty and may have to be
manually excluded.
If the auto-exclude option is disabled, the siren
will sound for the duration of reset time if a zone
is Unsealed at the end of exit time.
or... [User Code]
ARM
ARM
ENTER
ENTER
or...
The light should be off.Not ReadyThe light should be on.Ready
Press...Press...
The Armed light will turn on.
• Leave the premises within the Exit Delay Time.
• 3 beeps will sound at the end of Exit Delay Time.
The icon will turn on.
• Leave the premises within the Exit Delay Time.
• 3 beeps will sound at the end of Exit Delay Time.
[User Code]
LED KEYPAD
ARMING
LCD KEYPAD
NOTE: ARM ONLY codes
Normal user codes can arm the panel only if it is fully disarmed fi rst.
User codes that are programmed to be Arm Only codes can arm the panel from Monitor mode or from
the disarmed state.
See page 23 for User Code Programming.