Modem
Reference Manual for EL470 IP Satellite Modem
/Modem/Monitor/Modulation
Command
MoMonOutputFreq
Monitor output
frequency
Monitor output freq.
Location /Modem/Monitor/Modulation
Description
Readout of the modulator L-band monitoring output frequency.
RMCP
Command
MOF Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01ModulatorEntry
Command ntcDevsMod01MoMonOutputFreq
OID 1.3.6.1.4.1.5835.3.1.3.1.18.1.1
Values GUI Unit
MHz
Cmd Unit Factory Default (CU)
Hz 1.450.000.000
Expert Range (CU)
0 .. 99000000000
Command
MoMonSpectInv
Monitor out spec. inv. Monitor out spec. in
Location /Modem/Monitor/Modulation
Description
Readout of the output spectrum polarity.
RMCP
Command
MOS Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01ModulatorEntry
Command ntcDevsMod01MoMonSpectInv
OID 1.3.6.1.4.1.5835.3.1.3.1.19.1.1
Values Factory Default
directSpectrum
Enumeration Value
Direct spectrum
Inverted spectrum
1
2
Command
ODMeasPow
OD power supply OD power supply
Location /Modem/Monitor/Modulation
Description
Monitored value of the power supply to power the outdoor unit. If the
measured voltage is below +6V, the control command to enable/disable
the outdoor unit power supply will be suppressed.
RMCP
Command
opm Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01ODUEntry
Command ntcDevsMod01ODMeasPow
OID 1.3.6.1.4.1.5835.3.1.14.1.15.1.1
Values GUI Unit
Volt
Cmd Unit Factory Default (CU)
Volt 0
Expert Range (CU)
0 .. 26
version 3.1
146
SHAPING THE FUTURE OF SATELLITE COMMUNICATIONS