EasyManua.ls Logo

Newtec EL470 - Page 244

Default Icon
275 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Modem
Reference Manual for EL470 IP Satellite Modem
Command
IfComTxSig
Interface output signal
selection
Output signal
Location /Modem/Test/Modulation
Description
Configuration of the output signal placed on all outputs of the interface
board.
By default the active external interface input signal is brought back out.
When an additional processing function is present (e.g. the rate adapter)
the output of the processing block can be selected.
For testing purposes, a test generator signal can be routed to the output
(local loopback).
The selection off disables the output signal.
Remark: The output signal selection is independent of the input interface
type selection.
RMCP
Command
COS Access Normal user : no access
Expert user : RW
SNMP Table ntcDevsMod01InterfaceEntry
Command ntcDevsMod01IfComTxSig
OID 1.3.6.1.4.1.5835.3.1.4.1.44.1.1
Values Factory Default
rxsignal
Enumeration Value
Off
Rx sig.
TG
Proc. sig.
AIS
Buffer
0
1
2
3
4
5
Command
ODUSSPAARfAlTrippoint
HPA RF power alarm
level setpoint
HPA power alarm setp
Location /Modem/Test/Modulation
Description
Configuration of the high power amplifier RF alarm level set-point.
RMCP
Command
THt Access Normal user :
no access
Expert user : RW
SNMP Table ntcDevsMod01ODUEntry
Command ntcDevsMod01ODUSSPAARfAlTrippoint
OID 1.3.6.1.4.1.5835.3.1.14.1.6.1.1
Values GUI Unit
W
Cmd Unit Factory Default (CU)
W 0
Expert Range (CU)
0 .. 9999