Unit Menu
Reference Manual for EL470 IP Satellite Modem
Command
SyPPCVer1
PPC boot version PPC boot version
format : any chars
Command
SySnmpVer1
SNMP daemon version SNMP daemon version
Location /Unit/Architecture
Description
Readout of the SNMP daemon version and release date.
RMCP
Command
SDv Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01SystemEntry
Command ntcDevsMod01SySnmpVer
OID 1.3.6.1.4.1.5835.3.1.1.1.68.0.1
Values Factory Default
NA
String Description
length : 0 .. 25
format : any chars
Command
SyDevHwVer1
Device hardware
version
Hardware version
Location /Unit/Architecture
Description
Readout of the device hardware version.
RMCP
Command
Hve Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01SystemEntry
Command ntcDevsMod01SyDevHwVer
OID 1.3.6.1.4.1.5835.3.1.1.1.13.0.1
Values Factory Default
<press OK>
String Description
length : 0 .. 5
format : any chars
Command
SyDevHwCapab1
Device hardware
capability
Hardware capability
Location /Unit/Architecture
Description
Readout of the hardware configuration of the device. It can only be
changed by installing or removing hardware modules.
Capability = 0 corresponds to full device definition.
Capability = 255 corresponds to an illegal capability (="blocked" mode).
RMCP
Command
HWC Access Normal user : R
Expert user : R
SNMP Table ntcDevsMod01SystemEntry
Command ntcDevsMod01SyDevHwCapab
OID 1.3.6.1.4.1.5835.3.1.1.1.11.0.1
Values GUI Unit Cmd Unit Factory Default (CU) Expert Range (CU)
version 3.1
39