Product Manual, Issue 8 CMS100
www.nexo.comPage 52
110-120V line 220-240V line
voltage LO voltage LO
Disabled 0 170 17
80 8 180 18
90 9 190 19
100 10 200 20
110 11 210 21
Note: Voltage measurement is accurate to ± 10%
Caution
Low voltage protection is not calibrated and actual performance can be inuenced by
several factors. Therefore, total protection cannot be guaranteed.
6.3.23 High voltage (HI)
Display
Description
Denes the maximum voltage allowed before switching o the compressor. The high
voltage (HI) values are 10% of the actual line in voltages (see table below).
Considerations
Must not be used with an external voltage stabiliser
Must only be used with an Elstat supplied transformer
Global default 0 (disabled)
110-120V line 220-240V line
voltage HI voltage HI
Disabled 0 220 22
120 12 230 23
130 13 240 24
140 14 250 25
260 26
270 27
Note: Voltage measurement is accurate to ± 10%
Caution
High voltage protection is not calibrated and actual performance can be inuenced by
several factors. Therefore, total protection cannot be guaranteed.