GEO S12 HARDWARE SETUP PROCEDURE
Page 34 / 95 System Manual GEOS12 LS18
- Position angle plates and top counter-plates from GPI-ANPL to required GEO S12 inter-cabinet angle value between GEO
S12 upper sides according to figure below right
- Use thread lock coated screws (if not apply Loctite 243 or equivalent to shoulder screws) from LSI-CPLA and GPI-ANPL
kits
- Screw all shoulder screws so that all plates and cabinets are tightened together
- Flip the cluster upside down to access connector plates located on the down side
- Repeat all above steps
- Position the GPI-BUMPER bumper to required angle position and use the four shoulder screws to connect it the bumper to
the top cabinet
- Flip cluster by 90° so that it is ready to be positioned under the ceiling
- Four screws 12mm diameter (not provided) are required to secure the bumper under the ceiling