start updating
Select “start updating" if you want to start the update.
You are asked whether you really want to update the
software. Respond "yes" to continue or "no" to undo.
If you responded"yes" to the previous question the up-
date starts and you can now follow the progress of the
update on the display. When the update is complete
F1155 restarts.
NOTE
A software update does not reset the menu
settings in F1155.
NOTE
If the update is interrupted before it is com-
plete (for example power cut etc.), the software
can be reset to the previous version if the OK
button is held in during start up until the green
lamp starts to illuminate (takes about 10
seconds).
choose another file
update firmware7.1
Select “choose another file" if you do not want to use
the suggested software. When you scroll through the
files, information about the marked software is shown
in a fact box just as before. When you have selected a
file with the OK button you will return to the previous
page (menu 7.1) where you can choose to start the up-
date.
Menu 7.2 - logging
logging7.2
activated
interval
sec
5
Setting range: 1 s 60 min
Factory setting range: 5 s
Here you can choose how current measurement values
from F1155 should be saved onto a log file on the USB
memory.
1. Set the desired interval between loggings.
2. Tick activated".
3. The present values from F1155 are saved in a file in
the USB memory at the set interval until activated"
is unticked.
NOTE
Untick "activated" before removing the USB
memory.
Menu 7.3 - manage settings
manage settings 7.3
save settings
recover settings
Here you can manage (save as or retrieve from) all the
menu settings (user and service menus) in F1155 with a
USB memory.
Via "save settings" you save the menu settings to the
USB memory in order to restore them later or to copy
the settings to another F1155.
NOTE
When you save the menu settings to the USB
memory you replace any previously saved set-
tings on the USB memory.
Via "recover settings" you reset all menu settings from
the USB memory.
NOTE
Reset of the menu settings from the USB
memory cannot be undone.
NIBE F1155Chapter 9 | Service58

Other manuals for Nibe F1155 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1155 Series and is the answer not in the manual?

Nibe F1155 Series Specifications

General IconGeneral
RefrigerantR410A
Control SystemNIBE SMO 40
InstallationIndoor
Heating Capacity1.5-16 kW
Cooling CapacityNot applicable
Power Input CoolingNot applicable
EER CoolingNot applicable
Weight Outdoor UnitNot applicable
Dimensions Outdoor Unit (HxWxD)Not applicable
Dimensions Indoor Unit (HxWxD)600 x 620 mm