Technical specifications
FIGHTER 200P
26
Exhaust air fan power consumption (DC) 25–140 W
Required ceiling height 2 185 mm
Depth 615 mm
Total volume 240 liter
Water heater volume 170 liter
Supply voltage 230 V~ 1-phase + N
Immersion heater power rating 3,0 kW
Protection IP 21
Maximum pressure in double jacket vessel 0,25 MPa (2,5 bar)
Refrigerant quantity 420 g
Cut-in temperature for compressor 50 °C * (Controlled by a separate sensor)
Cut-in temperature for immersion heater 49 °C *
Setting area for the limiting valve 38 – 55 °C
Cut-out temperature, temperature limiter for immersion heater 88 °C
Sound power level** 46 – 50 dB(A)
Break pressure for high pressure pressostat 2,45 MPa (24,5 bar)
Break pressure for low pressure pressostat 0,15 MPa (1,5 bar)
Height (excl. feet 15-40mm) 2 095 mm
Width 600 mm
Net weight 195 kg
Volume in double jacket 70 liter
Expansion vessel volume, tap water 18 liter
Max operating current 16,7 A
Circulation pump power rating 100 W
Compressor power rating 550 W
Maximum pressure in water heater 0,9 MPa (9 bar)
Design pressure in double jacket volume 0,25 MPa (2,5 bar)
Refrigerant type R290 (propane)
Cut-out temperature for compressor 53 °C *
Cut-out temperature for immersion heater 52 °C *
Cut-out temperature, termostat for immersion heater 70 °C
Cut-out temperature, temperature limiter for compressor 88 °C
Sound level in room where installed*** 42 – 46 dB(A)
* Concerns settings on delivery
** A-weighted sound power level (LWA). The value varies with the selected fan curve.
*** A-weighted sound pressure level (LpA). The value varies with the damping capacity of the room.
These values apply with a damping of 4 dB.
Expansion vessel volume, heating system 12 liter
IP 21
For the Installer
Inlet temperature 40 °C
COP 2,60
Total Power input 0,535 kW
Exhaust air:
Air flow 150 m
3
/h
Inlet wet bulb temperature 12 °C
COP and heating capacity according to EN 14511-2:2004
Heating capacity 1,35 kW
Current 2,7 A
Rating condition
Inlet dry bulb temperature 20 °C
Water:
Outlet temperature 45 °C