15NIBE VVM 300
Installation
Pipe connections
F20XX
VVM 300
AV
AV
SÄV
SF
RC
TV
UG
Docking
The safety equipment must be installed in accordance with
current regulations for all docking options. See www.nibe.
com/docking for more docking options.
VVM 300 controls F20XX, which runs with floating con-
densation towards the heating system.
If F20XX cannot meet the heating requirement, additional
heat is shunted in from VVM 300. When the outside tem-
perature drops below the set stop temperature VVM 300
engages and takes over the heating.
VVM 300 docked to F20XX
Abbreviations
AV Shut-off valve
FG Flow line sensor
RG Return line sensor
RC Control valve
SF Particle filter (Included in F20XX)
SÄV Safety valve
TV Drain valve
UG Outside sensor
F20XX
VVM 300