55NIBE VVM 300
Miscellaneous
Technical specifications
Outside sensor
,3
Technical specifications
Height (excl. foot: 15 – 40 mm) 1 880 mm
Required ceiling height 2 000 mm*
Width 600 mm
Depth 615 mm
Weight 160 kg
Volume total 280 litres
Volume double jacket 125 litres
Volume, hot water heater 155 litres
Volume, expansion vessel 12 litres
Supply voltage 230 V~ 1-phase + N
Output immersion heater 6 kW
Rated output heating medium pump 45 / 75 / 110 W (adjustable)
Rated output charge pump 6 – 70 W (speed controlled)
Enclosure class IP21
Design pressure, hot water heater 1,0 MPa (10 (bar)
Cut-off pressure, hot water heater 0,9 MPa (9 (bar)
Max permitted pressure in double jacket volume 0,25 MPa (2.5 (bar)
Design pressure in double jacket volume 0,25 MPa (2.5 (bar)
Pre-pressure expansion vessel 0,5 bar (5 mvp)
Adjustable max boiler temperature 55 – 80 °C
Part no.
069 013
Enclosed kit
*The ceiling height becomes 1960 mm with the feet and front cover removed.