44 NIBE VVM 300
Miscellaneous
Menu 9.4 Quick start
If ”Yes” is selected, the compressor starts in the heat pump
within 3 minutes if there is a hot water heating demand.
Menu 9.5.0 Alarmlog
The alarm logs with the last 4 alarms are shown in the sub-
menus of this menu.
Menu 9.5.1.0 – 9.5.4.0 Log 1 – 4
Shows the last 4 alarms.
Menu 9.5.5.0 Return
Return to menu 9.5.0
Menu 9.5.x.1 Time
Shows the time of the actual alarm.
Menu 9.5.x.2 Alarm/Info
Shows information about the current alarm.
Menu 9.5.x.3 Hot water temperature
Shows the hot water temperature at the time of the cur-
rent alarm.
Menu 9.5.x.4 Supply temperature
Shows the heating system’s flow temperature at the time
of the current alarm.
Menu 9.5.x.5 Return temperature
Shows the heating system’s return temperature at the time
of the current alarm.
Menu 9.5.x.6 Outdoor temperature
Shows the outdoor temperature (outdoor temperature
sensor connected to the VVM) at the time of the current
alarm.
Menu 9.5.x.7 Run time compressor
Displays total compressor run time.
Menu 9.5.x.8 Acc. run time
Shows the run time on the compressor at the time of the
current alarm.
Menu 9.5.x.9 Operating mode
Shows the operating mode of VVM 300
and the heat
pump
at the time of the current alarm.
Menu 9.5.x.10 Outdoor temperature
Shows the outdoor air temperature at the time of the cur-
rent alarm.
Menu 9.5.x.11 Evaporator temperature
Shows the evaporator temperature at the time of the cur-
rent alarm.
Menu 9.5.x.12 Return temperature
Shows the outdoor unit’s return temperature at the time of
the current alarm.
Menu 9.5.x.13 Diff supply/return
Shows the difference between the flow line and return at
the time of the current alarm.
Menu 9.5.x.14 Suction gas temperature
Shows the suction gas temperature at the time of the cur-
rent alarm.
Menu 9.5.x.15 Hotgas temperature
Shows the hotgas temperature at the time of the current
alarm.
Menu 9.5.x.16 Liquid temperature
Shows the liquid line temperature at the time of the cur-
rent alarm.
Menu 9.5.x.17 Relay status 1-8
Shows the relay status on relays 1-8 at the time of the cur-
rent alarm.
Menu 9.5.x.18 Relay status 9-14
Shows the relay status on relays 9-14 at the time of the
current alarm.
Menu 9.5.x.19 Return
Return to menu 9.5.x.0
Menu 9.6.0 System Info
Only for service personnel.
Menu 9.7 Return
Return to menu 9.0.
Menu explanation