16 – ENGLISH
7.3 LEVEL 2 PROGRAMMING (ADJUSTABLE PARAMETERS)
All Level 2 parameters are factory-set as highlighted in “GREY” in “Table 7” and can be modied at any time. The parameters can
be adjusted to between 1 and 8. To verify the value corresponding to each LED, refer to “Table 7”.
7.3.1 Level 2 programming procedure
m
The user has maximum 10 seconds to press the buttons consecutively during the programming procedure,
after which time the procedure terminates automatically and memorises the changes made up to then.
To perform Level 2 programming:
1. press and hold the [Stop/Set] button until LED “L1” starts ashing
2. release the [Stop/Set] key when the “L1” LED starts ashing
3. press the [Open
p
] or [Close
q
] button to move the ashing LED to the “entry LED” associated with the parameter to be
modied
4. press and hold the [Stop/Set] button. With the [Stop/Set] button pressed:
– wait roughly 3 seconds, until the LED representing the current level of the parameter to be modied lights up
– press the [Open
p
] or [Close
q
] button to shift the LED associated with the parameter’s value
5. release the [Stop/Set] button
6. wait 10 seconds (maximum time) to exit the programming mode.
l
To set multiple parameters during the procedure's execution, repeat the operations from point 2 to point 4 dur-
ing the phase itself.
l
The set value highlighted in grey (“Table 7”) indicates that this value is the factory setting.
Table 7
LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)
Entry
LED
Parameter
LED
(level)
Set value Description
L1 Pause Time
L1 5 seconds
Adjusts the pause time, in other words, the time
before automatic re-closure. It is only effective if
the “Automatic Closing” function is enabled.
L2 15 seconds
L3 30 seconds
L4 45 seconds
L5 60 seconds
L6 80 seconds
L7 120 seconds
L8 180 seconds
L2
Step-by-Step
function
L1 Open - Stop - Close - Stop
Controls the sequence of controls associated with
the Sbs input or the 1st radio command.
L2 Open - Stop - Close - Open
L3 Open - Close - Open - Close
L4 Condominium
L5
Condominium 2 (more than 2 sec triggers
“Stop”)
L6
Step-by-Step 2 (less than 2 sec triggers “Partial
Open”)
L7 Hold-to-run
L8
Opening in “semi-automatic” mode, closing in
“hold-to-run” mode
L3 Motor speed
L1 Very slow
Adjusts the motor speed during normal
manoeuvres.
L2 Slow
L3 Medium
L4 Fast
L5 Very fast
L6 Extremely fast
L7 Opens “Fast”; closes “Slow”