13
4 INSTALLER SETTING PROGRAMMING
The factory default installer code is 9999.
To enter installer mode press   <installer code>
(the final is not required when using fixed length codes)
The keypad will beep 3 times and the Mode LED will alternately flash
Green and Orange ()
To exit installer mode press  , the keypad will sound 3 sets of 2
quick beeps.
The VST keypad will remain in Installer mode for 1 minute from the last
key press.
To program a setting use the following sequence:-
<setting number> <new value>
The keypad will respond with a Warble on successful programming or
with a Long Beep for unsuccessful.
In Installer mode the Status LED indicates the conditions below.
- Waiting for the start of a programming or exit sequence.
Green
-
was pressed as first key, waiting for a setting programming
sequence to be completed.
Red
-
was pressed as first key, waiting for an exit command to be
completed.
Red
-
Waiting for the Installer Code to be entered to confirm
programming of setting 961 or 969.
Each valid <setting number>, and its function, is described on the
following pages and a summary is provided in Appendix A on page 29.
All setting numbers are 3 digits long and the first digit is always 9.