13
4 INSTALLER SETTING PROGRAMMING
The factory default installer code is 9999.
To enter installer mode press <installer code>
(the final is not required when using fixed length codes)
The keypad will beep 3 times and the Mode LED will alternately flash
Green and Orange ()
To exit installer mode press , the keypad will sound 3 sets of 2
quick beeps.
The VST keypad will remain in Installer mode for 1 minute from the last
key press.
To program a setting use the following sequence:-
<setting number> <new value>
The keypad will respond with a Warble on successful programming or
with a Long Beep for unsuccessful.
In Installer mode the Status LED indicates the conditions below.
- Waiting for the start of a programming or exit sequence.
Green
was pressed as first key, waiting for a setting programming
sequence to be completed.
Red
was pressed as first key, waiting for an exit command to be
completed.
Red
Waiting for the Installer Code to be entered to confirm
programming of setting 961 or 969.
Each valid <setting number>, and its function, is described on the
following pages and a summary is provided in Appendix A on page 29.
All setting numbers are 3 digits long and the first digit is always 9.