5.1.3 Bulk Add User Codes Method
Often when initially setting up a system many user codes need to be
added. The bulk add method allows multiple codes to be added to
consecutive user locations with the minimum number of key presses.
NOTE: When using bulk add there is no indication as to whether the
user location being programmed already contains a code, and as such
any existing code will be overwritten with new one. It is therefore
recommended that this method only be used on a new installation.
The basic sequence is given below:-
<user location>
<code 1>
<code 2>
<last code>
Pressing a or instead of a starting digit for a code will cancel the
bulk add mode and start a new add, delete or exit manager mode
sequence.
Bulk add mode is automatically cancelled once a code has been added
to user location 500 or if a code is unable to be added due to it being
invalid or the same as one already in the system.
The <user level> and/or <output fields> can also be specified when
adding the codes using the following method:-
<code> <user level> <output mode>
Example
   - start bulk add at user location 100
    - save code 1234 in user location 100
    - save code 2345 in user location 101
     - save manager code 9876 in user location
102
       - save Auxiliary Lock code 3456 in user
location 103