EasyManua.ls Logo

Nidac VST62 - Setting 911 - Auxiliary Relay Time; Setting 912 - Auxiliary Lock Relay Mode; Setting 913 - Auxiliary REX Input Mode; Setting 914 - DOTL Time

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
4.5 Setting 911Auxiliary Relay Time
Allowed Values = 0 - 255 Default value = 10
The value for this setting is the time, in seconds, that the Auxiliary relay
uses for Auxiliary Lock control, key (door bell) activation, Door Forced
open alarm, Shunt or Direct Shunt.
Important note on 0 value for this setting
If the Auxiliary relay is set as key activation, shunt or direct shunt then
a 0 value will be converted to 1 second.
If the Auxiliary relay is set as Auxiliary Lock then a 0 value will cause the
Auxiliary relay to be in latching mode, making it alternate between open
and closed on each auxiliary code usage. The Auxiliary REX input will
also be disabled.
4.6 Setting 912Auxiliary Lock Relay Mode
Allowed Values = 0 - 1 Default value = 0
This setting only affects the Auxiliary relay if it is set as Auxiliary Lock
(Auxiliary Mode = 8 or 9).
Set the Auxiliary Lock relay as NO (Normally Open, Fail Secure) or NC
(Normally Closed. Fail Safe), 0 = NO, 1 = NC.
4.7 Setting 913Auxiliary REX Input Mode
Allowed Values = 0 - 3 Default value = 0
This setting only affects the Auxiliary input if it is set as Lock REX or
Auxiliary Lock REX (Auxiliary Mode = 1, 2, 3 or 8).
Sets how the Auxiliary REX input responds, 0 = NO momentary,
1 = NC momentary, 2 = NO continuous, 3 = NC continuous.
Please refer to the REX Input Mode (setting 903) on page 14 for a
description of these REX settings.
4.8 Setting 914DOTL Time
Allowed Values = 1 - 255 Default value = 30
When DOTL is enabled (Auxiliary Mode = 4 or 6) the value for this
setting is the time, in seconds, that the door can remain open before a
DOTL alarm is generated.

Table of Contents