16
Direct Shunt - The Auxiliary relay activates for Auxiliary Relay Time each
time a valid code or REX is used to operate the Lock relay.
This function is generally used to bypass (shunt) a door monitor sensor
or an alarm sensor covering the door area. Simply wire the Auxiliary
relay in parallel with the NC sensor and a valid code usage or REX will
shunt the sensor allowing door access without triggering an alarm
connected to the sensor.
Shunt - During normal operation when the door is locked, the Auxiliary
relay will mimic the status of the door sensor connected to the Auxiliary
Input. When a valid code or REX is used the Auxiliary relay will close for
the time set in Auxiliary Relay Time regardless of the status of the
Auxiliary Input.
This function is generally used to bypass (shunt) a door monitor sensor
or an alarm sensor covering the door area. Simply wire the NC sensor
between Auxiliary Input and 0V and wire the Auxiliary relay to the alarm
system in place of the sensor.
Door Open Too Long Alarm - The Auxiliary relay closes when the door
remains open for longer than the time set in DOTL Time, the relay will
release as soon as the door is closed again. The door sensor needs to
be connected to the Auxiliary Input for this function.
Door Forced Open Alarm ā When the door is opened without the use of
a code or REX the Auxiliary relay will close and remain closed until
either Auxiliary Relay Time has expired or the door is closed again,
whichever is the longer time. The door sensor needs to be connected to
the Auxiliary Input for this function.
DOTL and DFO Alarm - This setting provides for both the Door Open
Too Long and Door Forced Open alarms to be detected. When the door
is opened without
the use of a valid code or REX a DFO alarm is
detected. If the door is opened when the door is unlocked by a valid
code or REX the DOTL alarm comes into effect. The door sensor needs
to be connected to the Auxiliary Input for this function. Please refer to
the individual descriptions for DOTL and DFO for how they work.
Tamper - The Auxiliary relay will be closed during normal operation and
will open upon detection of a tamper event. The relay will close again
once the tamper alarm is cleared.