RECOVERY WATER SYSTEM
SERVICE MANUAL
ENGLISH
SC350 9098840000
17
RECOVERY WATER SYSTEM
VACUUM SYSTEM MOTOR ELECTRICAL INPUT CHECK
WARNING!
This procedure must be performed by qualied personnel only.
Remove the solution and recovery water tanks.1.
Apply the amperometric pliers (A) on the cable (B).2.
Turn the knob (32) to program (35).3.
Check that the motor electrical input is between 15 and 18 A at 12 V.4.
Turn the knob (32) to “0”.5.
Remove the amperometric pliers (B).
If the electrical input is higher than specied, disassemble the vacuum system motor (see the procedure in the relevant
paragraph), and check the condition of its moving parts.
If the procedure do not lead to a correct electrical input, it is necessary to replace the motor.