144Service Manual – SC401, SCRUBTEC 344 34 - Scrub System, Disc
Removal and Installation
Brush Deck
Removal
1. Drive the machine on a level oor or on a hoisting system to facilitate the disassembly procedures.
2. Remove the brush.
3. Switch off the machine and disconnect the battery connector.
4. Lower the brush deck by pressing the pedal
5. Under the machine, disconnect the detergent supply hose (A) from the detergent lter (B).
6. Unscrew and disconnect the connection (C) on the solenoid valve (D).
7. Remove the screws (E), (F) and (G) of the levers, then retain its bushings.
Figure 7:
C
D
G
F
E
A
B