68Service Manual – SC401, SCRUBTEC 344 05 - Control System - Cord
Parameter Description
Range
Resolution
Default
Permissions:
- = not visible
R = read only
W = read & write
Developer
Service/Tech
Production
NPI
Sales
Customer
Stopdelay Brush (ms) 0-25000 1 3000 W W R R - -
Stopdelay Vacuum (ms) 0-25000 1 5000 W W R R - -
T1on Pump state1 on time (ms) 5-255 1 7 W W R R - -
T1off Pump state1 off time (ms) 0-255 1 33 W W R R - -
T2on Pump state2 on time (ms) 5-255 1 17 W W R R - -
T2off Pump state2 off time (ms) 0-255 1 23 W W R R - -
T3on Pump state3 on time (ms) 5-255 1 40 W W R R - -
T3off Pump state3 off time (ms) 0-255 1 0 W W R R - -
Tm Pump time multiplier 1-255 1 100 W W R R - -