5.3 Electrical connection
The machine must be installed close to an
EEC regulation socket in a system which
conforms to the regulations in force with:
-
magnetothermal protection;
-
automatic differential switch;
-
grounding system.
Before connecting, verify that the electric
supply mains is suitable for the machine
by checking the technical data plate on the
machine.
The slicer is fitted with a power supply cord
of about 2m length, complete with a plug to
allow a simple disconnection from the electric
supply mains. ALWAYS indicate the presence
of the power supply cord if the slicer cannot
be installed near a socket and if in the
installation zone there is a transit of people.
If the power supply cord is not long enough
you will require the technical assistance
service and do not proceed with a temporary
electrical connection.
5.4 Checking direction of blade rotation
(only for machines with three phase motor)
1. Start the machine;
2. Check the working light is on;
3. Check the blade rotates in the direction
indicated by the arrow (counterclockwise
looking at the machine from the side of the
blade cover);
4. If the blade goes round in the opposite
direction (clockwise) stop the machine
immediately and call a qualified person to
invert the feed wires of the plug.