8 Additional information
BU 0600 en-2319 203
Frequency inverter type
150 kHz – 30 MHz
SK 5xxP-250-123-A … SK 5xxP-550-123-A 20 m -
SK 5xxP-750-123-A … SK 5xxP-221-123-A 20 m 5 m
SK 5xxP-250-340-A … SK 5xxP-550-340-A
SK 5xxP-750-340-A … SK 5xxP-551-340-A 20 m 5 m
Table 23: EMC, max. shielded motor cable length with regard to compliance with the limit value classes
EMC overview of standards that are used in accordance with EN 61800-3
as checking and measuring procedures:
-related emission
EN 55011
(interference field strength)
EN 55011
Interference immunity EN 61000
-6-1, EN 61000-6-2
ESD, discharge of static electricity
EMF, high frequency electro
-magnetic
EN 61000-4-3 10 V/m; 80 – 1000 MHz
EN 61000-4-4 1 kV
Burst on mains and motor cables
-phase / phase-ground) EN 61000-4-5 1 kV / 2 kV
Cable-led interference due to high
frequency fields
EN 61000-4-6 10 V, 0.15 – 80 MHz
Voltage fluctuations and drops
Voltage asymmetries and frequency
changes
EN 61000-2-4 3 %; 2 %
Table 24: Overview according to product standard EN 61800-3
1
2
Brake resistance
(option)
3
shield angle
4
Functional
earthing
PE
Figure 12: Wiring recommendation