BU 0600 en-2319 203
Frequency inverter type
Conducted emissions 1
150 kHz 30 MHz
Class C2
Class C1
SK 5xxP-250-123-A … SK 5xxP-550-123-A 20 m -
SK 5xxP-750-123-A … SK 5xxP-221-123-A 20 m 5 m
SK 5xxP-250-340-A … SK 5xxP-550-340-A
20 m
-
SK 5xxP-750-340-A … SK 5xxP-551-340-A 20 m 5 m
Table 23: EMC, max. shielded motor cable length with regard to compliance with the limit value classes
EMC overview of standards that are used in accordance with EN 61800-3
as checking and measuring procedures:
Interference emission
Cable
-related emission
(interference voltage)
EN 55011
C2
C1 (size 1-4)
Radiated emission
(interference field strength)
EN 55011
C2
-
Interference immunity EN 61000
-6-1, EN 61000-6-2
ESD, discharge of static electricity
EN 61000-4-2
6 kV (CD), 8 kV (AD)
EMF, high frequency electro
-magnetic
fields
EN 61000-4-3 10 V/m; 80 1000 MHz
Burst on control cables
EN 61000-4-4 1 kV
Burst on mains and motor cables
EN 61000-4-4
2 kV
Surge (phase
-phase / phase-ground) EN 61000-4-5 1 kV / 2 kV
Cable-led interference due to high
frequency fields
EN 61000-4-6 10 V, 0.15 80 MHz
Voltage fluctuations and drops
EN 61000-2-1
+10 %, -15 %; 90 %
Voltage asymmetries and frequency
changes
EN 61000-2-4 3 %; 2 %
Table 24: Overview according to product standard EN 61800-3
1
FI
2
Brake resistance
(option)
3
shield angle
4
Functional
earthing
PE
Protective earth
Figure 12: Wiring recommendation