8.8 Definition of setpoint and actual value processing (frequencies)
The frequencies used in parameters (P502) and (P543) are processed in various ways according the
following table.
Function Name Meaning
Output to ... without
Right/
Left
with
Slip
I II III
8 Setpoint frequency
setpoint source
X
1 Actual frequency Setpoint frequency for motor
model
X
23
with slip
Actual frequency at motor
X X
19
master value
setpoint source
Master value
(free from enable correction)
X X
20
n R master value
Setpoint frequency for motor
model
Master value
(free from enable correction)
X X
24
Master value of
actual frequency
with slip
motorMaster value
(free from enable correction)
X X X
21
Actual frequency
without slip master
value
master value slip
Master value
X
Table 28: Processing of setpoints and actual values in the frequency inverter