3 Options
BU 0600 en-2319 59
3.2.4 Parameterisation
Switching to parameter mode is performed in different ways depending upon the operating states and
the enabling source.
1. If enabling is not present via the control panel, control terminals or a serial interface, switch-over
from the operating value display to parameterisation mode can be made directly with ▼ or ▲.
2. If an enable is present via the control terminals or a serial interface and the frequency inverter is
producing an output frequency, it is also possible to switch to the parameterisation mode directly
from the operating value display using the ▼ or ▲ keys.
3. If the frequency inverter has been enabled via the control panel (Start key) access to the parameter
is not possible via the control panel.
Changing parameter values
Each parameter has a parameter number P x x x. The significance and description of the
parameters can be found in Section 5 "Parameter".
1. Press or ▲, to access the parameter area. The display changes to the menu group display
P 0 _ _ ... P 8 _ _.
2. Press the Start key to open the menu group. All parameters are arranged in order in a ring
structure in the individual menu groups. It is therefore possible to scroll forwards and backwards
within this section.
3. Select the required parameter with or and press the OK key.
4. Change the setting withor ▲ and confirm the changed setting by pressing the OK key.
As long as a changed value has not been confirmed by pressing OK key, the value display will blink;
this value is not stored in the frequency inverter.
Press the ESC key to exit from the menu.