EasyManuals Logo

Nordson 3100V Series Customer Product Manual

Nordson 3100V Series
412 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
lnstallation
A
3-31
Table
A 3-5
SYSTEM SETTINGS Features
Feature
No.
Feature
Description
Default
Setting
Optional
Settings
0
1
2
3
6-19
4
5
20
21
22
23
Password
Password
Enable
System-Ready
Time Delay
Overtemperature
Setpoint
Celsius/
Fahrenheit
Global
Temperature
Band
lndividual
Temperature
Bands
(See
Note D.)
Sequential
or
Simultaneous
Startup
Display
Heater
Proportioning
System Warning
or Power
Notification
System
Ready or
Pump
Notification
Provides
a
turned on.
password
if
the
password
enable feature is
The
password
(321)
cannot
be changed.
Allows
you
to turn the
password
enable feature
on or
off. When
the
password
enable feature is
on,
operators
can view the
settings for TEMPERATURE,
SYSTEM SETTINGS,
or CLOCK.
To change
the
settings, operators
must enter
the correct
password
(321).
When the feature
is off, operators
can change
all settings without entering
a
password.
Allows
you
to specify the
amount of additional
time
needed for
the adhesive
to
melt
after all zones
have
reached
their setpoint temperatures.
At
the end of the
time delay,
the
READY
light turns on.
Allows
you
to specify the
maximum temperature
any
zone
can reach before
the system initiates
a fault
condition. This setting
should be at least
14
'C
(25
'F)
above the highest
operating
setpoint. The
system will not
allow
you
to set
the overtemperature
setpoint
lower than this,
or the operating
setpoint
higher.
(See
Note
A.)
Allows
you
to display temperature
measurements
in
Celsius
or Fahrenheit.
Allows
you
to specify
the degree to which
a
temperature may
deviate from
any
zone
before
the
system indicates an out-of-band
warning.
(See
Note B.)
Allows
you
to specify
the degree to which
a
temperature may deviate
for an individual
zone
before
the system initiates
a
warning.
(See
Note C.)
Allows
you
to specify
whether
the system will
perform
a sequential
startup
(internal
zones
and hose
zones
heat first, then
gun
zones)
or
simultaneous
startup
(all
zones
heat at once).
Allows
you
to display
the heater
proportioning
(a
flashing
INTERNAL, HOSE,
or GUN
light).
Allows
you
to change the
System Warning
output
contact to
aleft
remotely
located
operators
that a
system warning has
occurred
or that
power
is
on.
Allows
you
to change
the System Ready
output
contact
to alert remotely
located operators
that
the
system is ready
(up
to temperature)
or
that the
pump
is
on.
321
0
(off)
18
(minutes)
2',t81425
(.c/.F)
F
(Fahrenheit)
17t30
("c/.F)
17t30
('cl"F)
1
(sequential)
0
(no
display)
1
(warning)
1
(ready)
none
0
(off)
1
(on)
G-60
(minutes)
52-2461125475
('cl'F)
F
(Fahrenheit)
C
(Celsius)
6-2811
0-50
('cl'F)
6-2811 0-50
('cl'F)
0
(simultaneous)
1
(sequential)
0
(no
display)
'l
(show
display)
0
(power)
'1
(warning)
0
(pump)
1
(ready)
NOTE A:
B:
C:
The overtemperature
setting should
be at least 42
"C
(75
"F)
below the flash
point
temperature.
lf
you
enter a setting that
is
higher
than the
tank setpoint,
the
pump
will
start when
the tank reaches
its setpoint.
lf
you
enter a new
setting for this feature, the
new setting is
immediately
entered for
the individual zones
(Feature
Nos. 6-19).
However, it is not
saved as the setting for
Feature
No. 5. Feature
No. 5 always
returns
to the default
setting
of 6
oC
(10
'F).
D: Feature
No. 6
=
tank,
Feature
No. 7
=
grid,
Feature
Nos.
&-13
=
hoses
1-6, Feature Nos.
14-1g
=
guns
1-6
@
2000 Nordson
Corporation
All rights reserved
41-3000v
lssued 5/00
A3 EN-04-[3V-X-4XXyJ-1
3

Table of Contents

Other manuals for Nordson 3100V Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson 3100V Series and is the answer not in the manual?

Nordson 3100V Series Specifications

General IconGeneral
BrandNordson
Model3100V Series
CategoryMelting Machines
LanguageEnglish

Related product manuals