RTD-Style Hot Melt Hose
15
WARNING:
Air trapped in
the
hoses
and
guns
can spit molten
adhesive that
can cause severe burns. Shield the area and
the
operator before
triggering the
guns.
3. Trigger
all
guns
to relieve any trapped hydraulic
pressure.
4. Disconnect
the solenoids and/or the
photoeyes
to
prevent
accidental
triggering of the
guns.
5.
Reduce
air
pressure
to the
guns:
.
Systems
with
automatic
guns:
Reduce
gun
air
pressure
to zero
at the regulator.
WARNING: Place handgun
trigger locks
in
the
locked
position
and ALWAYS
hang the handgun by the hole in its handle.
Failure to do so can result
in accidental
gun
firing that can
cause severe burns.
Systems
with
handguns:
Place the
gun
trigger safety in the
locked
position
Hang the handgun
by the
hole
in its handle.
a
6.
Place
a
pan
under
the drain
valve
and drain the unit manifold by
following
the
procedure
described in
the applicator technical
manual.
7. Disconnect
the hose from the manifold.
CAUTION: Equipment damage can
occur
if the
applicator
drain
valve
is turned with anything other
than a screwdriver.
Use only
a
screwdriver
to turn the drain valve.
8. Use a screwdriver to open the
drain
valve.
9.
Allow
the manifold
to
drain
as completely as
possible.
10. Use
a screwdriver to close the drain valve.
I
o
o
2000 Nodson
Corporation
All rights ressrved
108 232E
lssued 1/00
Manual 45-21