CRC200R USER GUIDE ISSUE 02
5-11
T
i m
e
z
o
n
e
2
-
0
T
M
i n
: x
x
Enter a 2-digit number for the ‘To Minute’ of the first active period
in Time Zone 2 and press
.
T
i m
e
z
o
n
e
2
-
0
M
o
n
: N
O
Use the
key to toggle between ‘’yes’ and ‘no’, then press
.
When set to ‘yes’, the active period set above will be active on
that day of the week (Monday in this case).
Repeat this sequence for each day of the week. Ignore ‘Hol’
(holiday) as this is not supported in the current build.
T
i m
e
z
o
n
e
2
-
1
F
H
o u
r
: x
x
Repeat the above procedure for the second active period of Time
Zone 2. On completion, you will then be given the same set of
parameter options for Time Zone 3:
T
i m
e
z
o
n
e
3
-
0
F
H
o u
r
: x
x
Repeat the procedure for Time Zone 3.
Upon completion of all Time Zone parameters, the unit will move to the next sub-menu item.
5.5.5 Card Format
This sub-menu item is used to set the format of the card data that will be read to the CRC200R so
that it can identify the card number to check. Please refer to Appendix B for help on identifying the
required data.
This sub-menu item is automatically selected when the final parameter of ‘Timezones’ (or ‘Door
Open TZ’) has been entered.
To reach this sub-menu item from the initial display, press
once and then press repeatedly
until the ‘Installer’ screen is displayed, press
once again to enter the sub-menu, and press
repeatedly until the following screen is displayed:
C
a
r
d
F
o
r
m
a
t
Press
and carry out one the following two procedures according to the card format.
Display Action
C
a
r
d
F
o
r
m
a
t
M
a
g
The CRC200R supports:
Mag - Clock & Data (ISO/ABA Track 2) displayed as
Wiegand - Wiegand format (variable)
W26 – Standard 26 bit Wiegand.
Use the
key to select the required format and then press
.
The next set of parameters depend on the chosen format (no
further parameters are required for W26).