CRC200R USER GUIDE ISSUE 02
5-8
C
o
n
f i g
N
o
d
e
: x
Type a number to set the node identity of the unit & press
Applicable only to non-standalone units. Each unit within a chain or
sharing a memory module must be given a unique Node identity
between 0 and 31. (See notes 1 and 2)
C
o
n
f i g
R
d
r
1
A
T
B
:x
x
>
Enter the anti-timeback period for reader 1 in minutes (between 1 and
30 minutes) and then press
.
To disable anti-timeback, set this value to ‘0’.
C
o
n
f i g
R
d
r
2
A
T
B
:x
x
>
Enter the anti-timeback period for reader 2 in minutes (between 1 and
30 minutes) and then press
.
To disable anti-timeback, set this value to ‘0’.
C
o
n
f i g
P
a
s
s
w
o
r
d
O
f f
Press
to toggle the Password option ‘On’ or ‘Off’ and press
when the desired state is displayed. If set to ‘On’, you will be
prompted for a four-digit number. This number will then have to be
entered whenever programming mode is selected from the opening
display. (See note 3)
Once the password parameters have been entered, the next sub-menu item is displayed.
Note 1: With ‘Op Mode’ set to ‘LINE’, the use of the ‘Node’ parameters enables the unit to be
configured to work with dedicated PC software. Each controller on the network must have
a unique node number between 0 and 31.
Note 2: With ‘Op Mode’ set to ‘210’, the use of the ‘Node’ parameters enable the unit to be
configured to work with dedicated PC software. The extended time zone feature of
Norpass2 must be enabled to be compatible with this operating mode. Also, each
controller on the network must have a unique node number starting at 0.
Operating mode ‘210’ can also be used in a standalone CRC200R controller where
standard time zone features are not adequate for the application.
Note 3: If you forget the password, you must reset it as follows:
Remove the cover, disconnect power and short circuit the ‘Free exit’ pin on reader input 2
to the ‘0V common’ pin while you reconnect the power.
5.5.2 Set APB Mode
This sub-menu item allows you to activate anti-passback mode and set the associated parameters.
This sub-menu item is automatically selected when the final parameter of ‘Config’ has been
entered and
is pressed.
To reach this sub-menu item from the initial display, press
once and then press repeatedly
until the ‘Installer’ screen is displayed, press
once again to enter the sub-menu, and press
repeatedly until the following screen is displayed:
S
e
t
A
P
B
M
o
d
e
Press
and carry out the following procedure: