3. Operation
— 3-16 —
Function setting by direct input
Refer to the following, for an example, how to change the function of the output port PO7 to
“Output ZONEA (Zone A)” from “Output NEARA (Near position A)”.
1) Specify the output port number by the command PO to read out the setting of parameter FN.
(The function of “NEARA” is specified to the output port as the shipping set)
#
P
O7
FNNEARA;
GC0;
ST0.0
O P
ENT
7
SP SP
Input the SP
key to scroll down to the parameters GC and ST.
2) Change the function to the output “ZONEA”.
GC0;
ST0.0
?
FNZONEA
?_
N F OZ E N
A
ENT
Set the parameters GC and ST as the same manner above.
3) Input “?” while the prompt is “?” to confirm the settings.
?
?
FNZONEA;
GC0;
ST0.0
?
ENT
SP SP
Input the SP
key to scroll down to the parameters FN, GC and ST.
4) Input the ENT
key to terminate the editing.
ST0.0
?
#_
ENT