NTI ENTERPRISE ENVIRONMENT MONITORING SYSTEM
35
Time Settings Description
Time Zone Enter the appropriate time zone
Enable Daylight Saving Change to “Yes” to have the time change in accordance Daylight Saving Time rules
Set Date Enter the system date in MM-DD-YYYY format
Set Time Enter the system time of day in hh:mm:ss format
Enable NTP Change to “Enabled” to allow the ENVIROMUX to automatically sync up with a time server via
NTP
NTP server If the NTP is enabled, enter the Domain Name or IP address of the NTP server
NTP Frequency Enter the frequency (in minutes) for the ENVIROMUX to query the NTP server (minimum is 5
minutes)
E-mail Time Stamp Change to “Enabled” to allow the ENVIROMUX to automatically apply a time stamp to e-mail
messages sent to users
SMS Time Stamp Change to “Enabled” to allow the ENVIROMUX to automatically apply a time stamp to SMS
messages sent to users
Press <Tab> to highlight Save and press <Enter> to save before pressing <Esc> to exit.
Restore Default Settings
Select this option to restore the ENVIROMUX to the configuration settings it had upon receipt from the factory. Be careful!
This will erase all user configuration settings. Upon restoration, the ENVIROMUX will reboot. Allow 1 minute before trying to
reconnect and log in again.
Note: You can also restore settings to defaults from the “Restore Defaults” button on the front of the ENVIROMUX.
Figure 38- Text Menu-Restore Default Settings
Note: If “Restore Defaults” is used, the IP address will also be restored to its default address (192.168.1.21) with a login
name “root” and password “nti”. To restore the root password to “nti” without having to restore all default settings,
contact NTI for assistance.
To identify the IP address of the ENVIROMUX without restoring defaults, use the Device Discovery Tool (see main
manual for “Device Discovery Tool”- pg 21).

Table of Contents

Other manuals for NTI ENVIROMUX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NTI ENVIROMUX Series and is the answer not in the manual?

NTI ENVIROMUX Series Specifications

General IconGeneral
Product TypeEnvironmental Monitoring System
Temperature Range-40°C to 85°C
Power Supply12V DC or 24V AC
Network InterfaceEthernet 10/100 Mbps
Alarm NotificationsEmail, SNMP
Sensor Types SupportedTemperature, Humidity, Water, Airflow
Power12V DC or 24V AC
Operating Temperature-40°C to 85°C
MountingWall or Rack Mount
Communication InterfacesEthernet
Data LoggingYes
ComplianceCE, RoHS

Related product manuals