Output Terminal Isolated(maximum, from chassis ground)
When output terminal (+) and (+S) & (-) and (-S) is connected with metal short bar
(±60VDC)
When output terminal above is not connected with metal short bar
(±240VDC)
(
)
AC Input Ratings
Standard 220V ± 10% , 50~60Hz
Option 100V ± 10% , 50~60Hz
115V ± 10% , 50~60Hz
230V ± 10% , 50~60Hz
Maximum Input Power (full load)
≤900 VA
Cooling
Isolation DC-Fan
Operation Temperature
0℃ ~ 40℃ for full rated output. At higher temperatures,
the output current is derated linearly to 50% at 55℃ maximum temperature.
Output Voltage Overshoot & Undershoot (During voltage output setting)
No overshoot
No undershoot
Programming Language
SCPI(Standard Commands for Programmable Instruments)
State Storage Memory
Ten(10) user-configurable(voltage, current, OVP & OCP level) stored states
Cycling Mode Storage Memory
() ( )
One hundred(100) cycling mode-configurable(voltage, current, slope & delay time) stored
states and start / finish number of sequence and repeat count.
Calibration Interval
Precision 6 month
Recommended 1 year
Di i
Dimensions
Excepted the bumper 213mm(W) * 133mm(H) * 348mm(D) (=inch 8.4 * 5.2 * 13.7)
Included the bumper. 243mm(W) * 152.5mm(H) * 348mm(D) (=inch 8.4 * 5.2 * 13.7)
Weight
Net weigth 13.5kg
Gross weight 15kg