EasyManua.ls Logo

Oki MB441MFP - Using Snmpv3

Oki MB441MFP
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Changing Network Settings From the Web Page
-155-
Network Settings
8
You need to set the mail server to allow the machine to
send an e-mail. For details on the mail server setting, refer
to your network administrator.
If you use Internet Explorer 7, be sure to configure the
settings below before you send a test mail. In the browser,
select [Tools] > [Internet Options], then click [Custom
Level] on the [Security] tab. Then select [Enable] in
[Allow websites to prompt for information using
scripted windows].
1 Access the machine's web page and log
in as the administrator.
2 Select [Admin Setup].
3 Select [Network Manager]>[E-mail]>
[Send Settings].
4 Follow the on-screen instructions to
specify detailed settings.
5 Select [Set detail of the SMTP
Protocol].
6 If necessary, you can configure
[Security Settings], [Configure
attached information], and [Others].
7 Click [Send].
The network card reboots to enable the new
settings.
Regular Alert
1 Access the machine's web page and log
in as the administrator.
2 Select [Admin Setup].
3 Select [Network Manager]>[E-mail]>
[Alert Settings].
4 Enter an e-mail address to receive the
alerts.
5 Click [Setting] for the specified address.
[Copy] is useful when you want to apply the alert
conditions to another address..
6 Follow the on-screen instructions to
specify detailed settings.
7 Click [OK].
8 Click [View a summary of current
configuration] to check the current
settings, and then click [X] to close the
window.
You can also check the current settings of up to
two addresses on the main window. Select the
desired addresses to check from the list box.
9 Click [Send].
The network card reboots to enable the new
settings.
If there is no error specified, the alert e-mail is not sent.
Alert At Time of Error Occurrence
1 Perform steps 1 to 6 in "Regular Alert".
When an error or warning is selected to require
notification, a window will display to specify the
time between error occurrence and sending the
alert.
2 Specify the time to sending of an error
alert and then click [OK].
If you specify a longer time, you are only notified
of persisting errors.
3 Click [OK].
4 Click [View a summary of current
configuration] to check the current
settings, and then click [X] to close the
window.
You can also check the current settings of up to
two addresses on the main window. Select the
desired addresses to check from the list box.
5 Click [Send].
The network card reboots to enable the new
settings.
Using SNMPv3
When you use the SNMP manager that supports
SNMPv3, the management of the machine is
encrypted by SNMP.
1 Access the machine's web page and log
in as the administrator.
2 Select [Admin Setup].
3 Select [Network Manager]>[SNMP]>
[Setting].
4 Follow the on-screen instructions to
specify detailed settings.
5 Click [Send].
The network card reboots to enable the new
settings.
Memo
Your machine has an SNMP agent. You can confirm and
change the machine settings by a commercially available
SNMP agent. For the MIB of the machine, refer to the
software DVD-ROM and check the "README" file in the
[Misc] > [MIB] folder.

Table of Contents

Related product manuals