44952001TH Rev.2
7-39
Oki Data CONFIDENTIAL
7. TROUBLESHOOTING PROCEDURES
Error (Disable to restore)
No.
Category
PJL Status
Code
Error Warning Description
1 Error 40712 1
2
3
4
5
Inspection is required.
%ERRCODE%: SIP Error
Indicates that the
processing of Scan Image
Processing contller was
failed.
User must turn Off/ On
the power supply, if this
status occurred.
%ERRCODE%
=1 : RAM Check Error
=2 : Illigal parameters
=3 : Memory Overflow
=4 : Scanner Receiving
Time-out
=5 : Others (Fatal Error)
2 Error 40724 1
2
3
4
5
Please call service.
Scanner unit failed to detect printer
unit.
Indicates that scanner
and printer is not
connected.
This message is
displayed, if the
communication between
scanner and printer units
could not be started.
User must turn Off/ On
the power supply, if this
status occurred.
3 Error 40714 1
2
3
4
5
SIP Firmware Missing
Indicates that the
firmware in board can not
be detected.
No.
Category
PJL Status
Code
Error Warning Description
4 Error - 1
2
3
4
5
Inspection is required.
PU Flash Error
It is shown that PU
firmware has booted in
Loader mode.
Ifinitializationis
completed, it will change
to the status of no.20.
This status may
occur also in a user
environment. When it
occurs, the maintenance
by a maintenance
member is required
(equivalent to S/C).
Communication error
occurred between CU
and PU. PU firmware may
not be downloaded.
5 Error - 1
2
3
4
5
Inspection is required.
PU Communication Error
Displays that
communication to PU
firmware failed.
This status may
occur also in a user
environment. When it
occurs, the maintenance
by a maintenance
member is required
(equivalent to S/C).
If this status occurred
duringtheunitinitialinzing
the message is displayed
by English.
6 Error 40978 1
2
3
4
5
%PUFLASH% Flash Error PU flush error (Error
occurs during the
alteration of PU farm or it
failed in the alteration in
PU flush of such as LED
Head information.)
%PUFLASH%
PU
TR AY2
DUPLEX
IM