Technical data
67
8.5 Binary outputs
Binary output relays: BINARY OUTPUT 1...4
Number of binary outputs
4
AC loading
V
max
=300 V AC; I
max
=8 A; S
max
=2000 VA
DC loading
V
max
=300 V DC; I
max
=8 A; P
max
=50 W (refer to load limit curve)
Switch-on current
15 A (max. 4 s at 10 % duty-cycle)
Electrical lifetime
100000 switching cycles at 230 V AC / 8 A and ohmic load
Pickup time
Approx. 6 ms
Fall back time
Approx. 3 ms
Bounce time
Approx. 0.5 ms
Connectors
4 mm/0.16 " banana sockets
Insulation
Reinforced insulation from all SELV interfaces and from power
supply
The diagram below shows the load limit curve for DC voltages. For AC voltages, a maximum power of
2000 VA is achieved.
Figure 31: Load limit curve for relays on the binary outputs with DC voltages