A-7
Appendices
CJ-series PROFIBUS Master Unit Operation Manual for NJ-series CPU Unit (W509)
A-1 Differences in Available Functions Depending on the CPU Unit (NJ/CJ series)
to be Connected
App
The device variables for CJ-series Units that correspond to all bits 0 to 127 in words CIO n+17 to
n+24 are as follows:
CJ-series I/O memory address NJ-series device variables for CJ-series Unit
Word address Bit Variable name Description
CIO n+17 0 to 15 *_SlavNewDiagL Slave station 00 to 15
CIO n+18 16 to 31 *_SlavNewDiagL Slave station 16 to 31
CIO n+19 32 to 47 *_SlavNewDiagL Slave station 32 to 47
CIO n+20 48 to 63 *_SlavNewDiagL Slave station 48 to 63
CIO n+21 64 to 79 *_SlavNewDiagH Slave station 64 to 79
CIO n+22 80 to 95 *_SlavNewDiagH Slave station 80 to 95
CIO n+23 96 to 111 *_SlavNewDiagH Slave station 96 to 111
CIO n+24 112 to 125 *_SlavNewDiagH Slave station 112 to 125 (bits 126 and
127 are reserved by system)