54
Transistor Input Units Section 4-3
Connector Pin Arrangement
Wiring Attach a FUJITSU connector to the Transistor Input Unit and connect it to the
external devices.
Applicable Connectors
Three types of connectors can be attached to the cable depending on the
assembly method. When creating your own cables, use one of the following
connectors.
Cables with Connectors
When a Transistor Input Unit with a high-density connector is to be connected
to an OMRON I/O Block or a Connector-Terminal Block Conversion Unit, use
the cables listed in the following table (sold separately).
Pin number
Function
Pin number
Function
A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1
NC NC NC
V
IN IN IN ININ IN IN IN
06 05 04 03 01 000207
B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1
NC NC NC
V
IN IN IN ININ IN IN IN
14 13 12 11 09 0810
15
Manufacturer Model number Remarks
FUJITSU FCN361J024-AU Soldered
FCN363J024-AU Crimp
FCN367J024-AU/F Pressure-welded
Manufacturer Model number Device
OMRON XW2Z-@@@A Connector-Terminal Block
Conversion Unit
XW2B-20G4 or
XW2B-20G5
G79-@@@C I/O Block
G7TC-I@16