EasyManua.ls Logo

Omron NA5-12W series

Omron NA5-12W series
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Programmable Terminal
NA-series
Hardware
User’s Manual
V117-E1-08
NA5-15101
NA5-12101
NA5-9001
NA5-7001

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Omron NA5-12W series and is the answer not in the manual?

Omron NA5-12W series Specifications

General IconGeneral
SeriesNA5-12W
TypeTouch Terminal
Display Size12.1 inches
Display TypeTFT Color LCD
Touch PanelAnalog resistive
Brightness400 cd/m²
BacklightLED
Operating Temperature0 to 50°C
Storage Temperature-20 to 60°C
Protection RatingIP65 (front panel)
Power Supply Voltage24 VDC
MountingPanel mount
Resolution1280 x 800 pixels
Backlight Life50, 000 hours
Humidity10% to 90% RH (non-condensing)
Shock Resistance147 m/s², 3 times each in X, Y, and Z directions
Communication PortsEthernet, USB, Serial
Memory128 MB

Summary

Introduction to the NA-series Programmable Terminals

Hardware and Software Features

Details hardware features like high-resolution displays and dual Ethernet ports, and software features.

Configuration Units

NA Units Components and Functions

Details the components and functions of the NA Units, including front panel elements.

Installation and Wiring

Fail-safe Measures

Recommends power supply sequences and fail-safe measures for safe operation.

Installing NA Units

Provides precautions and detailed steps for installing NA Units in a control panel.

Wiring Methods

Details wiring procedures for power supply, Ethernet, and serial ports.

Control Panel Installation

Covers temperature, humidity, vibration, atmosphere, electrical environment, and grounding for panel installation.

System Program

System Program and Startup Status

Explains the system program's role and the NA Unit's startup states and error handling.

System Recovery Procedure

Details the procedure for system recovery to initialize the NA Unit to its default state.

NJNXNY Troubleshooter

Helps monitor and troubleshoot errors and events from NJ/NX/NY controllers.

Hardware Diagnostics

Checks and calibrates the touch panel, function keys, and LCD display.

Troubleshooting

Operation after an Error

Describes error statuses, including RUN indicator states and fatal/non-fatal errors.

Fatal Errors in the NA Unit

Lists fatal errors that stop NA Unit operation and prevent Sysmac Studio connection.

Correcting Fatal Errors

Provides steps to correct fatal errors like power supply, hardware, and system program issues.

Cannot Go Online with Sysmac Studio

Lists causes and corrections for issues preventing online connection with Sysmac Studio.

Troubleshooting Connection Paths

Provides troubleshooting steps for direct USB connection issues with Sysmac Studio.

Maintenance