E5@C Digital Temperature Controllers User’s Manual (H174)
I
Remote SP Lower Limit ............................... 5-60, 6-86
Remote SP Monitor ............................... 5-60, 5-61, 6-9
Remote SP Upper Limit ............................... 5-60, 6-86
RT ......................................................................... 6-77
RT (Robust Tuning) ............................................... 6-77
RUN/STOP ............................................................ 6-13
Scaling Lower Limit ............................................... 6-44
Scaling Upper Limit ............................................... 6-44
Set Point During SP Ramp .................................... 6-10
Set Point Lower Limit ............................................ 5-15
Set Point Upper Limit ............................................ 5-15
Setting Change Protect ........................................... 6-5
Soak Time ........................................... 5-42, 5-44, 6-31
Soak Time Remain ................................................ 6-13
Soak Time Unit ...................................................... 6-84
SP Lower Limit ...................................................... 6-45
SP Mode ............................................. 5-60, 5-61, 6-21
SP Ramp Fall Value ..................................... 5-17, 6-33
SP Ramp Set Value ..................................... 5-17, 6-33
SP Ramp Time Unit .............................................. 6-63
SP Tracking ......................................... 5-60, 5-61, 6-87
SP Upper Limit ...................................................... 6-45
SP0 to SP7 ............................................................ 6-26
ST (self-tuning) ............................................. 6-46, 6-67
ST Stable Range ................................................... 6-67
Standard or Heating/Cooling ................................. 6-46
Standby Sequence Reset ..................................... 6-64
SV Status Display Function ................................... 6-94
Temperature Unit .................................................. 6-44
Transfer Output Lower Limit .................................. 6-55
Transfer Output Signal .......................................... 6-53
Transfer Output Type ................................... 5-36, 6-54
Transfer Output Upper Limit .................................. 6-55
Wait Band ..................................................... 5-44, 6-32
Work Bit 1 to 8 OFF Delay .................................... 6-37
Work Bit 1 to 8 ON Delay ...................................... 6-37
password ............................................................ 5-20, 5-21
setting .................................................................... 5-21
PF Key (S Key) ................. 3-8, 3-9, 5-20, 5-34, 5-55, 6-5
PF setting .................................................................... 5-55
PID constants ............................................ 4-24, 4-26, 4-27
PID control .................................................................. 4-14
position-proportional control ........................................ 5-62
Potentiometer Input ..................................................... 2-70
potentiometer input error .................................... 5-32, 5-49
potentiometer input error (Position-proportional Models
Only) ......................................................................... A-18
power supply ............................................................... 2-61
process value/set point 1 ............................................ 4-50
process value/set point 2 ............................................ 4-50
program end ................................................................ 5-45
program end output ..................................................... 5-45
programless communications ....................................... 1-4
proportional action ...................................................... 4-30
proportional band ........................................................ 4-31
Protect Level ........................................................6-3, A-38
protection .................................................................... 5-19
Initial Setting/Communications Protect ................. 5-19
Operation/Adjustment Protect ............................... 5-19
PF Key Protect ...................................................... 5-20
Setting Change Protect ......................................... 5-20
Push-In Plus terminal blocks ......................... 2-2, 2-3, 2-58
PV change rate alarm ................................................. 4-36
PV status display ........................................................ 5-58
R
ratings ........................................................................... A-2
registering calibration data ............................................ 7-2
remote SP input .......................................................... 2-70
remote SP input compensation ................................... 5-61
removing the Main Unit ............................................... 2-13
removing the terminal block ........................................ 2-23
resistance thermometer calibration ............................... 7-7
RS-485 .................................................................2-71, A-5
run/stop control ........................................................... 5-12
S
sampling cycle ..............................................1-2, 4-36, A-4
sensor input setting ranges .........................................A-43
set point limiter ............................................................ 5-15
set points 0 to 7 ............................................................. 6-9
setting levels diagram ................................................. A-44
setting monitor/setting items ....................................... 5-57
setting output specifications ........................................ 4-15
setting the input type ................................................... 4-11
setting the set point (SP) ............................................. 4-20
setting the SP upper and lower limit values ................ 5-15
Setup Tool ports .......................................... 2-76, 2-77, 3-8
Shift Key (S Key) ......................................................... 3-9
shifting input values ...................................................... 5-3
shifting inputs ................................................................ 5-3
simple program function .............................................. 5-42
starting method ...................................................... 5-43
Simple Transfer Output ...................................... 5-39, 6-56
SP ramp ...................................................................... 5-17
alarms .................................................................... 5-18
operation at startup ............................................... 5-18
restrictions ............................................................. 5-18
SP0 to SP7 ................................................................. 5-11
specifications ................................................................ A-2
ST (self-tuning) ........................................................... 4-27
startup conditions .................................................. 4-27
ST stable range ........................................................... 4-28
standard control .......................................................... 6-46
standby sequences ..................................................... 4-38
Status Display Messages ............................................ 5-73
SV status display ........................................................ 5-58
switching the SP mode ............................................... 5-13

Table of Contents

Other manuals for Omron E5EC

Related product manuals