EasyManuals Logo

Omron FQ2-S Series User Manual

Omron FQ2-S Series
444 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #303 background imageLoading...
Page #303 background image
Command Control
FQ2-S/CH User’s Manual
for Communications Settings
301
5
Appendices
SYSDATA or SD
Acquire System Data
This command acquires the value set for the specified system data.
System data numbers and details: p. 222
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
System data number Specifies the number that corresponds to the system data to be acquired.
Acquired value Returns the specified system data.
SY ATA
CR
SD
System data number
(3 digits max.)
Command
Space
(0x20)
Delimiter
Delimiter
Command
or
DS
System data
number
(3 digits max.)
CR
Space
(0x20)
Delimiter
CR
OK
CR
Acquired
value
CR
ER
Delimiter
FQ2-S_CH_comm.book 301 ペー 01年626 木日 前1時4