Command Control
312
FQ2-S/CH User’s Manual
for Communications Settings
SETITEMFIGPARAM or SIFP
Set Inspection Item Measurement Region/Model Region
This command changes the range set as the measurement region or the model registration region for an
inspection item.
This command cannot set a new measurement region or model registration region.
When using this command, execute it for an inspection item that has already been set with a measurement
region or a model registration region.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Inspection item number Specifies the inspection item number. (0 to 31)
Region number Selects either a measurement region or a model registration region. The value that spec-
ifies each region differs according to the inspection item type.
*1
Figure number The measurement region or model registration region range registers a complicated
model or a measurement region by combining a maximum of 8 figures (rectangles, cir-
cles, and other shapes).
Of those figures, specify the figure to change the range of using this command with the
figure number.
*1
Use the Acquire Inspection Item Figure command to check the figure numbers assigned
to each figure in advance.
Acquire Measurement Region/Model Region Information Set for an Inspec-
tion Item: p. 283
Parameter 1 to parame-
ter 21
The values to be set as the measurement region or the model registration region are split
up and specified in parameter 1 through parameter 21.
*2
Region
number
(1 digit)
Figure number
(1 digit)
Command
Space
(0x20)
Delimiter
Space
(0x20)
Space
(0x20)
Space
(0x20)
Space
(0x20)
Inspection item number
(2 digits max.)
Space
(0x20)
Space
(0x20)
Inspection
item number
(2 digits max.)
Command
or
Region
number
(1 digit)
Figure
number
(1 digit)
Delimiter
Space
(0x20)
Space
(0x20)
Space
(0x20)
Parameter 1
Parameter 2
Parameter 21
Parameter 1
Parameter 2 Parameter 21
SE MF IGPARAM
CR
TI ET
ISPF
CR
...
...
Delimiter
CR
OK
CR
ER
Delimiter
FQ2-S_CH_comm.book 312 ペー 01年626 木日 前1時4