EasyManua.ls Logo

Omron FQ2-S4 - Controlling Operation and Outputting Data with FINS;TCP No-protocol Commands

Omron FQ2-S4
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Controlling Operation and Outputting Data with TCP No-protocol Communications
428
FQ2-S4 User’s Manual
ERRGET
Acquire Error Information
This command acquires the latest error code from the Sensor.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Error code Returns the latest error code. If there is no error history, the response is 00000000.
11-1 Error Histories: p. 452
ER
CR
RG TE
Command
Delimiter
00 0
CR
00 000
Delimiter
Model
CR
OK
Delimiter
CR
ER
Delimiter

Table of Contents

Related product manuals