External Reference Parameters
FQ2-S4 User’s Manual
529
Appendices
12
Search
External
refer-
ence
number
Category Data name Setting/Acqui-
sition
Data range Default Expres-
sion text
string
Logged data/
Judgement
parameter
0 Mea-
sure-
ment
result
Judgement Acquisition
only
−2: No judgement (not mea-
sured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not per-
formed error,
−14: Figure not registered
error,
−15: Out of range error
−2 JG Logged data
5 Correlation Acquisition
only
0 to 100 0 CR[0] to
CR[31]
Logged data
6 Position X Acquisition
only
−99,999.9999 to
99,999.9999
0 X[0] to
X[31]
Logged data
7 Position Y Acquisition
only
−99,999.9999 to
99,999.9999
0 Y[0] to
Y[31]
Logged data
8 Angle Acquisition
only
−180 to 180 0 TH[0] to
TH[31]
Logged data
9 Reference X Acquisition
only
−99,999.9999 to
99,999.9999
0 SX ---
10 Reference Y Acquisition
only
−99,999.9999 to
99,999.9999
0 SY ---
11 Reference angle Acquisition
only
−180 to 180 0 ST ---
12 Detection coordinate X Acquisition
only
−99,999.9999 to
99,999.9999
0 RX ---
13 Detection coordinate Y Acquisition
only
−99,999.9999 to
99,999.9999
0 RY ---
14 Count Acquisition
only
0 to 32 0 C Logged data
103 Output
parame-
ter
Reflect Setting/Acqui-
sition
0: Yes, 1: No 0 --- ---
121 Model
region
Rotation Setting/Acqui-
sition
0: No, 1: Yes 0 --- ---
122 Rotation angle upper
limit
Setting/Acqui-
sition
−180 to 180 180 --- ---
123 Rotation angle lower
limit
Setting/Acqui-
sition
−180 to 180 −180 --- ---
132 Detec-
tion coor-
dinate
Detection point X Setting/Acqui-
sition
−99,999.9999 to
99,999.9999
0 --- ---
133 Detection point Y Setting/Acqui-
sition
−99,999.9999 to
99,999.9999
0 --- ---
134 Mea-
sure-
ment
condition
Sub-pixel Setting/Acqui-
sition
0: No, 1: Yes 0 --- ---