EasyManua.ls Logo

Omron FQ2-S4 - Setup Procedure for 2 D-Code

Omron FQ2-S4
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reading 2D-codes
FQ2-S4 User’s Manual
4
Setting Up Inspections
121
Setup Procedure for 2D-code
Step 1 Selecting the Inspection Item
[Inspect] [Inspection]
Step 2 Teaching
For teaching, the region to measure and the 2D code within that region are set as read conditions. You can also
register the contents that was read from the 2D code as a verification condition in the master data.
Step 3 Verification Conditions: p. 122
[Inspect] [Inspection] [Add item.] [2D-code] [Settings] Tab Page
1 Press an unused inspection item number and press
[Add item.].
2 Press [2D-code].
4-3 Configuring Inspection Items: p. 94
1 Press [Teach].
2 Input an image of the 2D code.
3 Move the rectangle so that it surrounds the 2D code.
4 Press the [OK] Button.
5 Press [TEACH] on the lower right of the display.
6 The result of reading the 2D code that was displayed
will be displayed along with a confirmation dialog
box for registration in the master data.
7 Press [Yes] to register the read result in the master
data.
The master data contains the character strings from the
2D codes that are registered to verify whether the read
character strings match specific character strings.
8 Press [Back] to end teaching.
Drag the arrow ( ) at the bottom of the menu to display all of
the inspection items.
Note
Drag the rectangle
to move it.
Drag a corner to size
the rectangle.

Table of Contents