Inspecting with the Area Inspection Item
184
FQ2-S4 User’s Manual
Reflect in Total Judgement
You can specify whether to reflect the judgement results of an inspection item in the overall judgement. (The
default is to reflect them.)
[Inspect] − [Inspection] − [Add item.] − [Area] − [Details] Tab Page − [Output parameter]
Unstable Area Results
The Desired Color Cannot Be Detected
Add a specific color or enlarge the color range.
Extraction Is Automatically Performed for an Undesired Color When Teaching
Manually set the color for which to measure the area.
[Inspect] − [Inspection] − [Area] − [Modify] − [Settings] Tab Page − [Teach]
• Sensors with Color Cameras Only
Item Parameter Setting Description
Judgement Parameter Area Range: 0.00000 to 999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit: 0.0000
Set the upper and lower limits for an OK
judgement. The set range is the differ-
ence between the reference area and
the measured areas.
Gravity X Range: −999,999,999.9999 to
999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit: −999,999,999.9999
Set the upper and lower limits of the
range of gravity X that is to be judged
as OK.
Gravity Y Range: −999,999,999.9999 to
999,999,999.9999
Default: Upper limit: 999,999,999.9999,
Lower limit: −999,999,999.9999
Set the upper and lower limits of the
range of the gravity Y that is to be
judged as OK.
• You can change the output form for each measurement value to one of the following settings.
Press
[] − [Result type] on the right of the display.
Absolute value (default): The measured coordinates are output.
Relative value: The difference from the reference position is output as coordinates.
Ratio: The percentage of the reference value is output. (This applies to the area only.)
1 Press [ ] − [Set color] on the right of the display.
2 Drag around the color for which you want to measure
the area.
Areas with that color will be automatically detected.
Continuous measurements will be performed for the im-
ages that are displayed.
Only the extracted color will appear on the display.
3 Press [OK].
4 Press [TEACH].
5 Press [Back] to end teaching.
Note