Menu Tables
488
FQ2-S4 User’s Manual
TF settings
Ethernet --- System p. 53
Auto Used to automatically connect to the IP
address of the Touch Finder.
OFF (default), ON
Specify sensor You can set any of the Sensors for con-
nection to the Touch Finder and register
them.
0.0.0.0 to 223.255.255.254 (default:
0.0.0.0)
p. 248,
p. 249
IP address Inputs the IP address of the Touch
Finder.
(Valid only when the [IP address setting]
is set to [Fixed].)
a.b.c.d
a:1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
(Default: 10.5.5.100)
p. 53
Subnet mask Inputs the subnet mask.
(Valid only when the [IP address setting]
is set to [Fixed].)
0.0.0.0 to 255.255.255.255
(Default: 255.255.255.0)
p. 53
Gateway Sets the default gateway address. (When
the [IP address setting] is set to [Fixed].)
1.0.0.1 to 223.255.255.254
(Default: 10.5.5.7)
Search unreachable
sensors
Displays the IP address if the same IP
address is used for more than one Sen-
sor or if there is Sensor that is not in the
subnet. You can change this IP address
and subnet mask. This setting is valid
only when automatic setting of the Sen-
sor's IP address is OFF.
--- --- ---
Auto sensor detection The Touch Finder can detect Sensors
and automatically connect to them in the
order that it detects them.
ON (default), OFF p. 248
Logging setting You must enable file logging before you
can execute it.
ON (default), OFF p. 256
Language Changes the language to display on the
Touch Finder.
English, German, French, Italian, Span-
ish, Traditional Chinese, Simplified Chi-
nese, Korean, or Japanese (The default
language is selected at startup.)
System p. 277
Time settings Used to set the current date and time. Default: Selected at startup. System p. 277
Touch screen calib Used when there is an offset between
the touch screen positions and pointers.
--- --- p. 278
Initialize Initializes the Touch Finder settings. --- --- p. 277
Restart Restarts the Touch Finder. --- --- p. 277
Update Updates the Touch Finder system to the
most recent data.
--- --- p. 569
Menu command Description Setting range Data Refer-